Product Introduction
*Automated gain,Peak Hold and Peak Memory;
*Automated display precise flaw location(Depth d,level p,distance s,amplitude,sz dB,);
*Ten independence setup, any criterion can be input freely, we can work in the scene without test block;
*Big memory of 300 A graph and 30000 thickness value.
*Gate and DAC alarm;Acoustic-Optical alarm;
*RS232 port,communication with pc is easy;
*The embeded software can be online updated;
*Li battery, continue working time up to 7 hours;
*Other assistant function;
*Display freeze;
*Automated echo degree;
*Angles and K-value;
*Lock and unlock function of system parameters;
*Dormancy and screen savers;
*Electronic clock calendar ;
*Two gates setting and alarm indication;
*High-speed capture and very low noise;
*DAC,AVG; Solid metal housing (IP65);
*Provides high contrast viewing of the waveform from bright, direct sunlight to completae darkness and easy to read from all angles;
*Powerful pc software and reports can be export to excel;
Main Parameter
Designation Technical Data
Range of scanning (mm) Range of scanning (mm):2.5~60000(Steel Longitudinal wave)
Steps: 2.5,5,10,20, 30,40,50,60,70,80,90, 100,150,200, 250, 300, 350, 400, 450,500,600,700,800,900,1000,2000,3000,4000,5000,6000
Adjusting step: 0.1mm(2.5 mm~99.9mm),1mm(100mm~10000mm)
D-delay (ms) D-delay (ms):-20~+3400
Steps: -20,-10,0.0, 10, 20, 50,100,150,200,250,300,350,400,450,500, 600,
700,800,900,1000,1500,2000,2500,3000,3400.
Adjusting steps: 0.1(-20ms~999.9ms),1(1000ms~3400ms)
P-delay (ms) P-delay:0.0~99.99
Adjusting steps: 0.01
MTLVEL(m/s) MTLVEL:1000~9999
7 fixed levels: 2260,2730,3080,3230,4700,5920,6300
Adjusting steps:1
Working mode Single probe (receiving and sending), double probe (one for receiving and another for sending), transmission(transmission probe)
FrequencyRange (MHz) 0.4–20
Gain adjustment (dB) 0~110
Adjusting step: 0.0,0.2,0.5,1,2,6,12
Reject 0%~80% of screen height, step: 1%
Vertical linear error Vertical linear error is not more than 3%
Horizontal linear error Not more than 0.2% in the scanning range
Sensitivity Leavings ≥62 dB
Dynamic range ≥32dB
Alarm Three modes, i.e. forbidden wave, loss wave and auto
Monitoring door 2, expressed by bold transverse line, whose start, width and height are adjustable.
Adjusting range of start (mm): horizontal pixel 0~208, the displayed value is relative with the scanning range.
Step: value in mm corresponding to a pixel (relative with the scanning range)
Adjusting range of width (mm): horizontal pixel 4~212, the displayed value is relative with the scanning range.
Step: value in mm corresponding to a pixel (relative with the scanning range)
Adjusting range of height: 2%~90% of vertical graduation
Step graduation: 1%
Display Display: high-brightness lattice
A-Scan display area Full screen or local
A-Scan display freezing and de-freezingA-Scan filling
Data save 300 A-Scan images (including setting of instrument)
30000 values of thickness (300 sets)
Standard interface RS232 for communication with PC
Measuring unit mm/inch
Battery Li battery 4×3.6V4800mAh
Power adaptor Input 100V~240V/50Hz~60Hz
Output 9V~12VDC/1.5A
Working temperature -20°C~70°C
Working humidity 20%~90%
Port type BNC
Dimension (mm) 240×180×50
Weight (kg) 1.8