HPC400 petrol and diesel car automobile exhaust gas analyzer

m.chinacoalintl.com
chinacoal05
we provide service of enterprise's customs declaration, inspection.
Main Feature
1.The large screen liquid crystal display,English menu.                    
2.The use of German imports of infrared detector, O2 sensor, vibration     resistance, good stability, high precision.                               
3.The measurement of CO, HC, CO2 ,O2, COcor concentration and the lambda value, speed, temperature, flow, pressure.                             
4.With the single, double idle idle, general measuring function.              
5.It can be measured with diesel, gasoline, LPG, CNG and alcohol as a fuel for vehicle.            
6.According to the new standard and the United States BAR97standards  development, in line with the ISO3930or OIMLR99 I level precision.
7.With the automatic zero adjustment, automatic cleaning, automatic temperature compensation, pressure compensation.                             
8.With the HC residue measurement, traffic monitoring, gas leak check.                 
9.The machine has self diagnostic function, fault when prompted, until the troubleshooting can continue measurement.
10. With speed, temperature measurement, built-in printer(or the analog output interface or RS -232A digital serial communication interface) or digital (Analog ) interface network.
11.The license plate number input and 2000 groups of data storage, reference function, clock display.

Technical parameters

Item
Date
Measuring range 
HC:0~10000×10-6(ppm)vol    CO:0~10×10-2(%)vol
CO2:0~20×10-2(%)vol         O2:0~25×10-2(%)vol
R.M.P: 0-9999r.m.p           OIL TEMP:0-150
Lambda: 0.5~1.5              COcor:010×10-2(%)vol
Indication error 
HC ± 12×10-6(ppm) vol 
(absolute error)or± 5% (relative error)
CO± 0.06×10-2(%) vol   
(absolute error)or± 5% (relative error)
CO2 ±0.5×10-2 (%) vol   
(absolute error)or± 5% (relative error)
O2 ±0.1×10-2(%) vol     
(absolute error)or± 5% (relative error)
Repeatability
Repetition error+/- 2% 
Stability
Automatic zero, volume moments drift  ± 3%
Resolution
HC:1×10-6(ppm)vol      CO:0.01×10-2(%) vol
CO2:0.1×10-2(%) vol        O2:0.01×10-2(%) vol    
Lambda: 0.01             R.P.M:10r.p.m,  OIL TEMP:0.1
Response time
95% repose time no more than 10 seconds
Warm up time 
8min ( Emergency detection can be preheated 3 min ) 
Output Mode 
Digital direct-reading show gases ,can be attached printer to print name, the maximum, average and minimum concentration,can test time, date, etc.Can be attached to interface with the computer network.
Environmental conditions
Temperature-5 ~ 50 , relative humidity 90%
Power
AC100-240V 50/60Hz or DC12V                 (Choose add power inverter)
Consumption Power 40VA 
Dimensions
(with bracket) 
420mm (L) x 310mm (W) x 170mm (H)
Weight 
About 9kg