2016年9月18日星期日

ZBL-C310A Rebar Corrosion detector

sales@chinacoalintl.com
m.chinacoalintl.com
Chinacoal05
1. The C310A provides the ability to examine the corrosion potential and to locate active corrosion in rebar in building structures. The procedure is virtually non-destructive and is performed by carrying out a grid based measurement.

2. The C310A Rebar Corrosion Detector is a specialized apparatus designed according to the electro chemical testing method (natural potential method). C310A tests the potential concrete surfaces through a Cu/CuSO4 referenceelectrode, and determines the level of rebar corrosion.


Features:
The C310A includes a two electrode handle system which provides flexibility for the operator to:
Test using one electrode based on half cell potential method.
Test using two electrodes based on gradient method. In both cases, electrodes used are copper sulfate type.
Automatic storage option is available in instrument         -
Data transfer to USB-thumb drive is available.
The device generates rebars corrosion potential contour graph
Software Provided for Data Processing of Corrosion Potential Measurement : Is an Easy
to Use Powerful processing software
provided for generation of reports Operates on windows based computers..




Items
Specifications
Corrosion detection method
single electrode
Double electrode
Measuring Range(mV)
±1000
0-1000
Accuracy(mV)
±0.1
±0.1
Tested points Interval X
0-100 adjustable
20 fixed,
Tested points Interval Y
0-100 adjustable
0-100 adjustable
Screen
160x128
Bettery operating Time(h)
>40
Power
Built-in rechargeable lithium battery
Data transmission
USB thumb drive storage
Data storage
234 points
Test area(m²)
234( tested point interval 100cm)
Size(mm)
212x134x50
Electrode Size(mm)
30x180
Weight(kg)
0.9