sales@chinacoalintl.com
m.chinacoalintl.com
Chinacoal05
1. The C310A provides the ability to examine the corrosion potential and to locate active corrosion in rebar in building structures. The procedure is virtually non-destructive and is performed by carrying out a grid based measurement.
2. The C310A Rebar Corrosion Detector is a specialized apparatus designed according to the electro chemical testing method (natural potential method). C310A tests the potential concrete surfaces through a Cu/CuSO4 referenceelectrode, and determines the level of rebar corrosion.
Features:
The C310A includes a two electrode handle system which provides flexibility for the operator to:
Test using one electrode based on half cell potential method.
Test using two electrodes based on gradient method. In both cases, electrodes used are copper sulfate type.
Automatic storage option is available in instrument -
Data transfer to USB-thumb drive is available.
The device generates rebars corrosion potential contour graph
Software Provided for Data Processing of Corrosion Potential Measurement : Is an Easy
to Use Powerful processing software
provided for generation of reports Operates on windows based computers..
Items
|
Specifications
| |
Corrosion detection method
|
single electrode
|
Double electrode
|
Measuring Range(mV)
|
±1000
|
0-1000
|
Accuracy(mV)
|
±0.1
|
±0.1
|
Tested points Interval X
|
0-100 adjustable
|
20 fixed,
|
Tested points Interval Y
|
0-100 adjustable
|
0-100 adjustable
|
Screen
|
160x128
| |
Bettery operating Time(h)
|
>40
| |
Power
|
Built-in rechargeable lithium battery
| |
Data transmission
|
USB thumb drive storage
| |
Data storage
|
234 points
| |
Test area(m²)
|
234( tested point interval 100cm)
| |
Size(mm)
|
212x134x50
| |
Electrode Size(mm)
|
30x180
| |
Weight(kg)
|
0.9
|